• Année
  • 1939
  • Catégorie
  • Radio - ou tuner d'après la guerre 1939-45
  • Radiomuseum.org ID
  • 54301
    • alternative name: RCA Manufacturing || Victor Talking Machine

Cliquez sur la vignette du schéma pour le demander en tant que document gratuit.

 Spécifications techniques

  • No. de tubes
  • 13
  • Principe général
  • Super hétérodyne avec étage HF; FI/IF 455 kHz
  • Gammes d'ondes
  • PO et 2 x OC
  • Tension / type courant
  • Alimentation Courant Alternatif (CA)
  • Haut-parleur
  • HP dynamique à électro-aimant (électrodynamique) / Ø 12 inch = 30.5 cm
  • Puissance de sortie
  • 20 W (qualité inconnue)
  • Matière
  • Boitier en bois
  • De Radiomuseum.org
  • Modèle: K130 Ch= RC-501A - RCA RCA Victor Co. Inc.; New
  • Forme
  • Console avec des boutons-poussoirs
  • Dimensions (LHP)
  • 32.375 x 44 x 17 inch / 822 x 1118 x 432 mm
  • Remarques
  • Doors. Motorized tuning.
    This model has 3 power supply ratings:
    Rating A...105-125V, 50-60 Cycles
    Rating B...105-125V, 25-60 Cycles
    Rating C...105-130;140-160;200-250V, 40-60 Cycles
  • Poids net
  • 63.56 lb (63 lb 9 oz) / 28.856 kg
  • Prix de mise sur le marché
  • 159.95 USD
  • Source extérieure
  • Ernst Erb
  • Source du schéma
  • Rider's Perpetual, Volume 11 = ca. 1940 and before

 Collections | Musées | Littérature

Collections

Le modèle K130 fait partie des collections des membres suivants.

 Forum

Contributions du forum pour ce modèle: RCA RCA Victor Co.: K130 Ch= RC-501A

Discussions: 1 | Publications: 1

Some tips for repairing the motorized tuning system on the RCA K130 and other similar models:

First I had to replace the AC motor drive capacitor, which is a 60 uF 24 VAC nonpolarized electrolytic capacitor. I used back-to-back (the two + ends connected) polarized electrolytic capacitors, first trying two 50 uF 50 VDC capacitors, and then two 100 uF 50 VDC capacitors. The two 100 uF capacitors provided better motor torque, so I went with those.

Although it worked OK without them, I also added 1N4007 diodes across each capacitor to prevent any reverse polarity voltage from damaging the caps.  This might extend the life of the replacement capacitors.

If the motor runs a long time (more than a minute -- much longer than needed for the tuning to operate), the caps start to get a little warm, but they seem to be holding up just fine.  The original cap is marked "intermittent usage," so I imagine these replacement caps have similar capability.

Also found that the rubber drive "wheel" on the motor shaft was hard as a rock and would not grip its mating metal wheel. Simply using the spinning motor shaft itself as a lathe with a little knife blade, I turned down the rubber to remove about half of it, and exposing the end of the metal shaft. Then I glued a plain rubber grommet to the remaining hard rubber and metal shaft with cyanoacrylate glue ("Super Glue," which sticks super well to rubber!). It works really well, with quiet, smooth operation, and plenty of torque transfer. Very simple fix for an otherwise difficult to obtain part.

The insulation on the two wires connected to the rotating split plate on the rear of the tuning capacitor was in bad shape, so I replaced those wires with modern very finely stranded (highly flexible) wire.  This should hold up well for many years.

After these fixes, the motorized tuning system works perfectly.

Tom
 

Thomas Albrecht, 12.Mar.12