A1998

Information - Help 
ID = 37205
       
Country:
Great Britain (UK)
Brand: Osram-Valves GB (not MO-Valves)
Tube type:  Ionisation or Vacuum Gauge 
Identical to A1998

Base Wires Wires only.
Was used by Industrial
Filament If 0.66 Ampere
Description Ionization gauge. All glass bulb, with 3mm. stem as standard; 16 mm. stem can be used for higher sensitivity. Filament voltage must be adjusted for the required emission value: typically about 6V during outgassing and about 4V in normal operation. Sensitivity as high as 150 microamps per micron can be expected.

Va <250, Pa<22W 

Dimensions (WHD)
incl. pins / tip
46 x 128 x mm / 1.81 x 5.04 x inch