Electronic Testmeter MkII 4019

AVO Ltd.; London

  • Año
  • 1951–1955 ?
  • Categoría
  • Aparato de medida y servicio (Equipo de laboratorio).
  • Radiomuseum.org ID
  • 230686

 Especificaciones técnicas

  • Numero de valvulas
  • 2
  • Tensión de funcionamiento
  • Red: Corriente alterna (CA, Inglés = AC) / 100 - 130 / 200 - 260 Volt
  • Altavoz
  • - - No hay salida de sonido.
  • Material
  • Metálico
  • de Radiomuseum.org
  • Modelo: Electronic Testmeter MkII 4019 - AVO Ltd.; London
  • Forma
  • Formas varias descritas en notas aparte.
  • Anotaciones
  • Voltmetro amperometro elettronico con lettura di: resistenze, tensioni, correnti, capacità e potenza d'uscita

    Valve Voltmeter and Component Bridge.

    Uses a separate electronic probe fitted with D77 or 6AL5, which may be missing on collected examples (dual diode). The 6SN7 is a dual triode used as bridge amplfier for the moving coil meter. 50Hz or 60Hz supply. Some UK Home market variants are 190V to 260V 50Hz only and may use a series "bathtub" capacitor "dropper" on mains input.. Consumption about 17W. Metal Rectifier for HT.

    Easily transportable rectangular metal cabinet with handle on side. Must be used with an earthed mains.

    Version Identification

    1. MK I: The meter movement at the bottom of the panel and the switches above and used two EF50 pentodes (c1947 to 1950). Version not marked.
    2. MKII: This version using a single 6SN7. Version not marked.
    3. There is no MkIII
    4. MK IV:  used a 12AU7 (ECC82, etc). Marked as Mk IV,

    Lamps/Bulbs:

    • Movement 6.5V 0.3A
    • Dials 3.5V 0.3A x 2 (currently available 3.5A 0.2A will work)

    Measurements

    • DC Volts 11 M Ohms input impedance: 250mV to 1000V F.S.D. in 8 ranges
    • DC Volts using x10 external multiplier: 110 M Ohms input impedance 2.5V to 10kV F.S.D. in 8 ranges
    • AC Volts internal probe:  1V to 250V F.S.D. in 6 ranges (low frequency only)
    • AC Volts external probe:  1V to 250V F.S.D. in 6 ranges (limited at higher  frequencies) 20KHz to 200MHz, below 100V above 50MHz.
    • AC Volts, High potential lead in x10 socket,  internal probe:  10V to 2500V F.S.D. in 6 ranges (low frequency only)
    • DC current, 250mV drop  : 25uA to 1A F.S.D. in 8 ranges
    • dB rel 50mW: 50mW or 5W. Internal Load 5, 10, 25, 200, 600 or 5000 Ohms. -10dB to +10dB
    • AC power: 500mW or 5W. F.S.D. Internal Load 5, 10, 25, 200, 600 or 5000 Ohms.
    • Capacitance:  100pF to 500nF OR 10nF to 50uF  (Bridge) 10V RMS max applied. (two ranges)
    • Resistance: 0.2 to 1000, 20 to 100K or 2K to 10M  (bridge), maximum 0.25V applied. (3 ranges)
    • Megaohms: 0.1 M  to 1000 M Ohms, 2.5V maximum voltage applied, not a Leakage test, though called "insulation" in manual.
  • Peso neto
  • 5 kg / 11 lb 0.2 oz (11.013 lb)
  • Ext. procedencia de los datos
  • AVO Electronic Testmeter Working Instructions
  AVO Electronic Testmeter Working Instructions (AVO Electronic Testmeter MkII 4019, AVO ETM2) 1301 KB
  • Documentos sobre este modelo
  • Autor
  • Modelo creado por Gianni Vecchietti. Ver en "Modificar Ficha" los participantes posteriores.

 Colecciones | Museos | Literatura

Colecciones

El modelo Electronic Testmeter MkII es parte de las colecciones de los siguientes miembros.

 Forum