Portable Oscilloscope V-509

Hitachi Ltd.; Tokyo

  • Année
  • 1987 ??
  • Catégorie
  • Appareils de mesure et de dépannage (matériel de labo)
  • Radiomuseum.org ID
  • 204143
    • alternative name: Hitachi Sales Corp. of America

 Spécifications techniques

  • No. de tubes
  • 1
  • Lampes / Tubes
  • No. de transistors
  • Semi-conducteurs présents
  • Semi-conducteurs
  • Gammes d'ondes
  • - sans
  • Tension / type courant
  • Secteur et Piles (tous types). / 220 / ? Volt
  • Haut-parleur
  • - - Pas de sortie basse fréquence
  • Matière
  • Boitier métallique
  • De Radiomuseum.org
  • Modèle: Portable Oscilloscope V-509 - Hitachi Ltd.; Tokyo
  • Forme
  • Portative > 20 cm (sans nécessité secteur)
  • Dimensions (LHP)
  • 220 x 110 x 340 mm / 8.7 x 4.3 x 13.4 inch
  • Remarques
  • Bandwidth: DC to 50 MHz
    2 channels with 1 mV sensitivity
    Delayed sweep
    AC or DC input
    Type: rectangular mesh tube Hitachi 95 LB 31 with 12 kV acceleration potential and metal with the support of phosphorus.
    Display Type: P31 phosphorus (GH) standard
    Useful screen size: 8 x 10 div (1 div = 6.35 mm) internal graticule
    Z Input: DC-coupled continuous positive signal intensity decreases.
    5V signal p-p - DC to 1 MHz
    Vertical deformation (2 identical channels)
    Bandwidth and rise time: DC to at least 50 MHz and 7.0 ns rise time or less.
    Deviation Factor: 5 mV / div to 5 V / div in 10 calibrated steps, 1-2-5 sequence.
    Uncalibrated continuous control between steps
    x 5 Extender extends the type of deviation min. 1 mV / div.
    Display Modes: CH1, CH2 (normal or reverse), alternate, chopped (rate of 250 kHz), added.
    Input Impedance: 1 M ohm in parallel with 30 pF
    Maximum input voltage: 250 V (DC + peak AC)
    Delay Line: Allows viewing of displayed waveform edge.
    CH1 Output: DC 10 MHz
    Horizontal deflection:
    Base Sequence Time: 0.1 µs/div to 0.2 s/div in 20 calibrated steps, 1-2-5.
    Uncalibrated continuous control between steps.
    x 10 Magnifier enlarges faster sweep speed to 10 ns/div.
    Base Sequence B time: 0.1 µs/div of 2 ms/div in 14 calibrated steps, 1-2-5
    x 10 Magnifier enlarges faster sweep speed to 10 ns/div.
    Horizontal display modes: Single, intensified, B delayed
    Calibrated sweep delay: Continuous calibration control
    Activation and b
    Shooting modes: Auto, Normal, single sweep, TV-V, TV-H
    A trigger Hold Off: Adjustable control permits a stable display of complex repetitive waveform.
    Trigger source: Internal (CH1, CH2), line, external, external x 10
    B trigger and source modes: Auto, Normal
    X-Y operation (CH1 Horizontal, Vertical CH2)
    Deviation Factor: Same as vertical deflection
    Bandwidth: DC to at least 500 kHz
    Phase error: 3 degrees or less from DC to 100 kHz
    Gauge: 0.5 V + / -1% square wave frequency of 1 kHz
    Battery: 2 hours continuous
  • Poids net
  • 5 kg / 11 lb 0.2 oz (11.013 lb)