Portable frequency counter PFM1300

Thurlby Thandar Instruments

  • Année
  • 1995
  • Catégorie
  • Appareils de mesure et de dépannage (matériel de labo)
  • Radiomuseum.org ID
  • 305339
    • alternative name: Thandar Electronics || TTI

 Spécifications techniques

  • Gammes d'ondes
  • Bandes en notes
  • Tension / type courant
  • Piles sèches / 9 Volt
  • Haut-parleur
  • - - Pas de sortie basse fréquence
  • Matière
  • Plastique moderne (pas de bakélite, ni de catalin)
  • De Radiomuseum.org
  • Modèle: Portable frequency counter PFM1300 - Thurlby Thandar Instruments
  • Forme
  • Portable, appareil de poche. Taille < 20cm
  • Dimensions (LHP)
  • 81 x 30 x 178 mm / 3.2 x 1.2 x 7 inch
  • Remarques
  • The TTi PFM1300 is a portable battery-operated frequency counter with a range of 5 Hz to 1.3 GHz that uses a reciprocal counting technique to achieve 7 significant digits of frequency or period answer per second of measuring time.
    The timebase has a 10 MHz crystal oscillator with an initial adjustment tolerance of +-2 ppm. The temperature coefficient is typically less than +-0.3 ppm per degree C, and the ageing rate is less than +-5 ppm per year.
    A user-accessible trimmer on the rear of the case allows recalibration without dismantling.
    8-digit LCD display.
    Trig indicator.
    User-selectable 50 kHz low pass filter.
    Hold function.
    BNC input sockets. 

    Input A
    5 Hz to 25 MHz.
    1 Mohm/25 pF, AC coupled.
    Resolution 0.0001 mHz to 10 Hz.
    Accuracy +-(1 digit + timebase accuracy).
    Sensitivity sinewave 15 mV rms, 10 Hz to 20 MHz.
    Maximum input 30v rms, reducing to 1v rms above 1 MHz.
    Period measurement available, measurement time 0.1, 1, or 10 seconds.

    Input B
    20 MHz to 1.3 GHz.
    50 ohms nominal.
    Resolution 1 Hz to 1 kHz.
    Accuracy +-(1 digit + timebase accuracy).
    Sensitivity 10 mV rms 20 MHz to 700 MHz, 50 mV rms to 1.3 GHz. 
    Maximum input 30v rms, reducing to 1v rms above 20 MHz.

    Powered by a 9v PP3 alkaline battery, with a life of about 12 hours.
    'Bat' display indicates that 10% of battery life remains.
    Push-to-measure function extends battery life by switching off the instrument after 15 seconds.

    The PFM1300 was superseded by the model PFM3000 offering frequency measurement up to 3 GHz.

  • Poids net
  • 0.190 kg / 0 lb 6.7 oz (0.419 lb)
  • Auteur
  • Modèle crée par Bruce Taylor. Voir les propositions de modification pour les contributeurs supplémentaires.