Test Set Electronic Valve C.T.160
Avo (Brand), Automatic Coil Winder and Electrical Equipment Co., Avo Ltd; London
- Country
- Great Britain (UK)
- Manufacturer / Brand
- Avo (Brand), Automatic Coil Winder and Electrical Equipment Co., Avo Ltd; London
- Year
- 1960
- Category
- Service- or Lab Equipment
- Radiomuseum.org ID
- 113160
Click on the schematic thumbnail to request the schematic as a free document.
- Number of Tubes
- 2
- Valves / Tubes
- D77
- Wave bands
- - without
- Power type and voltage
- Alternating Current supply (AC) / 105-120; 175-250 Volt
- Loudspeaker
- - - No sound reproduction output.
- Material
- Metal case
- from Radiomuseum.org
- Model: Test Set Electronic Valve C.T.160 - Avo Brand, Automatic Coil
- Shape
- Tablemodel, low profile (big size).
- Dimensions (WHD)
- 255 x 295 x 370 mm / 10 x 11.6 x 14.6 inch
- Notes
-
Static and Dynamic Characteristic (Mutual Conductance (mA/V))
Anode Volts: 20, 40, 60, 75, 90, 100, 150, 200, 250, 300, 400V
Screen Volts: 20, 40, 60, 75, 90, 100, 125, 150, 200, 250, 300V
Neg. Grid Volts: 0 / -40V adjustable
Anode Current: 0 / 90mA & 0 / 10mA
Set mA/V: 1, 20mA/V slop control
Mains Voltage Selector: 110, 180, 200, 220, 240V & -5 / 0 / +5 / +10V
Heater Volts Switch 0,625 -117 position:
0,625 /1,25/ 2,0/ 2,5/ 4/ 5/ 6,3/ 10/ 11/ 13/ 16/ 20/ 25/ 30/ 48/ 70/ 117V
Heater Volts Switch 1,4 - 80 position
1,4/ 3/ 4,5/ 5,7/ 12,6/ 15/ 18/ 23/ 28/ 35/ 45/ 55/ 80V
- Net weight (2.2 lb = 1 kg)
- 11 kg / 24 lb 3.7 oz (24.229 lb)
- Literature/Schematics (1)
- - - Data from my own collection
- Author
- Model page created by Hernani Capela. See "Data change" for further contributors.
- Other Models
-
Here you find 82 models, 79 with images and 41 with schematics for wireless sets etc. In French: TSF for Télégraphie sans fil.
All listed radios etc. from Avo (Brand), Automatic Coil Winder and Electrical Equipment Co., Avo Ltd; London
Collections
The model Test Set Electronic Valve is part of the collections of the following members.
Forum contributions about this model: Avo Brand, Automatic: Test Set Electronic Valve C.T.160
Threads: 1 | Posts: 3
Dear members,
For a few days I'm trying to calibrate my AVO CT160 valve tester. I downloaded all the mauals and articles I could find, read the calibration parts several times. Did the calibration step by step. I checked all the resistors in the instrument (up till now I didn't check the capacitors and potmeters). Replaced the calibration resistors R3 and R4. And last but not least I made a calibration tube (ECL80) in the way it is described in the AVO manual. Checking the instrument with my new made calibration tube I found out that on the low end the Ia measurements from the AVO is a little to high (10%). In the middel it is oke and with higher Ia settings values from the AVO are lower (15%) than expected. Gm measurement is fine. Anyone who has experience with calibration of a AVO CT160? A little help is appreciated.
Regards,
Paul
Attachments
- My AVO CT160 (91 KB)
Paul Cornelissen, 03.Nov.08