Mesureur de Champ - Field Strength Meter VX 409 B

Metrix, Compagnie Générale de Métrologie; Annecy

  • Year
  • 1970 ??
  • Category
  • Service- or Lab Equipment
  • Radiomuseum.org ID
  • 304481

Click on the schematic thumbnail to request the schematic as a free document.

 Technical Specifications

  • Number of Transistors
  • 12
  • Semiconductors
  • Main principle
  • Superheterodyne (common); ZF/IF 37000 kHz
  • Wave bands
  • VHF incl. FM and/or UHF (see notes for details)
  • Power type and voltage
  • Batteries / addl. power jack / 4 x 4.5 / 18 Volt
  • Loudspeaker
  • Permanent Magnet Dynamic (PDyn) Loudspeaker (moving coil) / Ø 4 cm = 1.6 inch
  • Power out
  • 0.25 W (max.)
  • Material
  • Metal case
  • from Radiomuseum.org
  • Model: Mesureur de Champ - Field Strength Meter VX 409 B - Metrix, Compagnie Générale de
  • Shape
  • Portable set > 8 inch (also usable without mains)
  • Dimensions (WHD)
  • 290 x 155 x 160 mm / 11.4 x 6.1 x 6.3 inch
  • Notes
  • Input impedance 75 Ω ±20%

    Three frequency ranges:
    41 - 120 MHz
    120 - 230 MHz
    470 - 860 MHz

    Calibration accuracy ±2%
    Frequency stability ±0.2%

    Six signal strength ranges, with full scales:
    10 µV, 300 µV, 1 mV, 3 mV, 10 mV, 30 mV.

    Measurement accuracy:
    ±3 dB VHF ranges 1 and 2
    ±6 dB UHF range 3

    AM and FM detectors for sound channel output.
    Supplied in a leather carrying case.

  • Net weight (2.2 lb = 1 kg)
  • 6 kg / 13 lb 3.5 oz (13.216 lb)
  • Author