Data Analyzer 308

Sony-Tektronix, Tokyo

  • Année
  • 1980
  • Catégorie
  • Appareils de mesure et de dépannage (matériel de labo)
  • Radiomuseum.org ID
  • 246928

 Spécifications techniques

  • No. de tubes
  • 1
  • Lampes / Tubes
  • No. de transistors
  • Semi-conducteurs présents
  • Semi-conducteurs
  • Gammes d'ondes
  • - sans
  • Tension / type courant
  • Alimentation Courant Alternatif (CA) / 90-132; 180-250 Volt
  • Haut-parleur
  • - - Pas de sortie basse fréquence
  • Matière
  • Plastique moderne (pas de bakélite, ni de catalin)
  • De Radiomuseum.org
  • Modèle: Data Analyzer 308 - Sony-Tektronix, Tokyo
  • Forme
  • Modèle de table générique
  • Dimensions (LHP)
  • 237 x 117 x 359 mm / 9.3 x 4.6 x 14.1 inch
  • Remarques
  • The 308 is a 20 MHz, four-in-one portable Data Analyzer. It provides Parallel Timing, Parallel State, Serial State and Signature Analysis.


    Signal Inputs
    Parallel Timing & State
    Multliine probe-tip, 8 Data lines, 1 clock & 1 ground lead.
    Maximum Number of Inputs: 8
    Input Impedance: 1 MΩ, 5 pF

    Logic Swing
    Minimum: 500mV +2% of threshold voltage p.p. centered on threshold  voltage.
    Maximum: ±40V or less, to at least threshold voltage Maximum Non-destructive Input Voltage: -40V to +40V
    Width of Data input: Minimum 10ns, with 400mV overdrive from threshold voltage

    Threshold Voltage — Selectable
    TTL: +1.4v to +0.2 volts
    VAR: -12 volts to +12 volts

    Input mode — selectable
    Sample or Latch (to 5ns with 500mV overdrive voltage)

    Serial State
    Single channel probe Input
    Input Impedance: 10 MΩ, 13 pF

    Nondestructive Maximum Input Voltage:
    500 V peak at probe tip
    250 peak at bnc input connector

    Logic Swing
    Minimum: 500mV +2% of threshold voltage, peak-topeak centered about the threshold
    Maximum: ±30V peak
    Selectable Parity: ODD, EVEN or NONE
    Selectable Bits Per Character: 5, 8, T or 8 bits (includes parity if active).

    Selectable Input logic: Positive or Negative (at probe tip)
    Synchronizing Word (Synchronous mode only): Programmable to require two equal words. It not programmed defaults to ASCII word SYN.

    Hunt Word (Synchronous Mode Only): Programmable to require one word. If not programmed, defaults to "XXXXXXXX" (Not defined). One Hunt word is equal to 3 Hexadecimal "FF"s (Line idles).

    Stop Bits (ASYNC ONLY): Responds to one or more

    Signature Analyzer
    Single channel data input via probe: 10MΩ; 13pF Clock start, and stop Inputs provided by Data Acquisition probe.

    Clock
    Parallel Timing & State
    External Clock: Period Minimum 50 ns

    Pulse Width, Minimum: High-Logic Level: 24.5ns;  Low-Logic Level:  24.5ns
    Data Setup Time, minimum: 25ns
    Data Hold Time, minimum:    0ns
    Internal Clock: 20 MHz
    Sample Interval, minimum: 50ns

    Data Pulse Width to ensure sampling
    Minimum: 1 sample interval +10ns
    Sample Intervals: 50ns to 200ns/sample in 1-2-5 sequence

    Qualifier Input
    Selectable Trigger or Clock
    Input Threshold: TTL Level +1.4V ± 0.2 volts
    Maximum Input Voltage: -5V to +10 V peak

    Memory
    8 x 252 bits Data Acquisition Memory
    8 x 252 bits Reference Memory
     

  • Poids net
  • 4.5 kg / 9 lb 14.6 oz (9.912 lb)
  • Prix de mise sur le marché
  • 3,000.00 USD
  • Littérature
  • -- Original prospect or advert
  • Auteur
  • Modèle crée par Pius Steiner. Voir les propositions de modification pour les contributeurs supplémentaires.

 Collections | Musées | Littérature

Collections

Le modèle Data Analyzer fait partie des collections des membres suivants.