Data Analyzer 308
Sony-Tektronix, Tokyo
- País
- Japon
- Fabricante / Marca
- Sony-Tektronix, Tokyo
- Año
- 1980
- Categoría
- Aparato de medida y servicio (Equipo de laboratorio).
- Radiomuseum.org ID
- 246928
- Numero de valvulas
- 1
- Válvulas
- Numero de transistores
- Hay semiconductores.
- Semiconductores
- Gama de ondas
- - no hay
- Tensión de funcionamiento
- Red: Corriente alterna (CA, Inglés = AC) / 90-132; 180-250 Volt
- Altavoz
- - - No hay salida de sonido.
- Material
- Plástico moderno (Nunca bakelita o catalina)
- de Radiomuseum.org
- Modelo: Data Analyzer 308 - Sony-Tektronix, Tokyo
- Forma
- Sobremesa de cualquier forma, detalles no conocidos.
- Ancho, altura, profundidad
- 237 x 117 x 359 mm / 9.3 x 4.6 x 14.1 inch
- Anotaciones
-
The 308 is a 20 MHz, four-in-one portable Data Analyzer. It provides Parallel Timing, Parallel State, Serial State and Signature Analysis.
Signal Inputs
Parallel Timing & State
Multliine probe-tip, 8 Data lines, 1 clock & 1 ground lead.
Maximum Number of Inputs: 8
Input Impedance: 1 MΩ, 5 pF
Logic Swing
Minimum: 500mV +2% of threshold voltage p.p. centered on threshold voltage.
Maximum: ±40V or less, to at least threshold voltage Maximum Non-destructive Input Voltage: -40V to +40V
Width of Data input: Minimum 10ns, with 400mV overdrive from threshold voltage
Threshold Voltage — Selectable
TTL: +1.4v to +0.2 volts
VAR: -12 volts to +12 volts
Input mode — selectable
Sample or Latch (to 5ns with 500mV overdrive voltage)
Serial State
Single channel probe Input
Input Impedance: 10 MΩ, 13 pF
Nondestructive Maximum Input Voltage:
500 V peak at probe tip
250 peak at bnc input connector
Logic Swing
Minimum: 500mV +2% of threshold voltage, peak-topeak centered about the threshold
Maximum: ±30V peak
Selectable Parity: ODD, EVEN or NONE
Selectable Bits Per Character: 5, 8, T or 8 bits (includes parity if active).
Selectable Input logic: Positive or Negative (at probe tip)
Synchronizing Word (Synchronous mode only): Programmable to require two equal words. It not programmed defaults to ASCII word SYN.
Hunt Word (Synchronous Mode Only): Programmable to require one word. If not programmed, defaults to "XXXXXXXX" (Not defined). One Hunt word is equal to 3 Hexadecimal "FF"s (Line idles).
Stop Bits (ASYNC ONLY): Responds to one or more
Signature Analyzer
Single channel data input via probe: 10MΩ; 13pF Clock start, and stop Inputs provided by Data Acquisition probe.
Clock
Parallel Timing & State
External Clock: Period Minimum 50 ns
Pulse Width, Minimum: High-Logic Level: 24.5ns; Low-Logic Level: 24.5ns
Data Setup Time, minimum: 25ns
Data Hold Time, minimum: 0ns
Internal Clock: 20 MHz
Sample Interval, minimum: 50ns
Data Pulse Width to ensure sampling
Minimum: 1 sample interval +10ns
Sample Intervals: 50ns to 200ns/sample in 1-2-5 sequence
Qualifier Input
Selectable Trigger or Clock
Input Threshold: TTL Level +1.4V ± 0.2 volts
Maximum Input Voltage: -5V to +10 V peakMemory
8 x 252 bits Data Acquisition Memory
8 x 252 bits Reference Memory
- Peso neto
- 4.5 kg / 9 lb 14.6 oz (9.912 lb)
- Precio durante el primer año
- 3,000.00 USD
- Mencionado en
- -- Original prospect or advert
- Autor
- Modelo creado por Pius Steiner. Ver en "Modificar Ficha" los participantes posteriores.
- Otros modelos
-
Donde encontrará 7 modelos, 7 con imágenes y 1 con esquemas.
Ir al listado general de Sony-Tektronix, Tokyo
Colecciones
El modelo Data Analyzer es parte de las colecciones de los siguientes miembros.