Concertino Hi-Fi Stereo 5093W
Telefunken Deutschland (TFK), (Gesellschaft für drahtlose Telegraphie Telefunken mbH
- Hersteller / Marke
- Telefunken Deutschland (TFK), (Gesellschaft für drahtlose Telegraphie Telefunken mbH
- Jahr
- 1959 ?
- Kategorie
- Rundfunkempfänger (Radio - oder Tuner nach WW2)
- Radiomuseum.org ID
- 110227
Klicken Sie auf den Schaltplanausschnitt, um diesen kostenlos als Dokument anzufordern.
- Anzahl Röhren
- 9
- Anzahl Transistoren
- Hauptprinzip
- Superhet allgemein; ZF/IF 460/10700 kHz; Exportmodell
- Wellenbereiche
- Mittelwelle, 2 x Kurzwelle plus UKW (FM).
- Betriebsart / Volt
- Wechselstromspeisung / 115; 230 Volt
- Lautsprecher
- 3 Lautsprecher
- Material
- Gerät mit Holzgehäuse
- von Radiomuseum.org
- Modell: Concertino Hi-Fi Stereo 5093W - Telefunken Deutschland TFK,
- Form
- Tischgerät, Tasten oder Druckknöpfe.
- Abmessungen (BHT)
- 24 x 14 x 10.5 inch / 610 x 356 x 267 mm
- Bemerkung
-
Telefunken Concertino Hi-Fi Stereo 5093W (Hi-Fi System) is an export model with MW (515 - 1630 kHz), 2 SW (2.2 - 6.9 MHz and 6.8 - 22.5 MHz), and FM (87.5 - 108 MHz) ranges.
It has 3 loudspeakers: 1 elliptical full range 18 x 26 cm and 2 tweeters Ø 10 cm.
See also the similar model Concertino Hi-Fi Stereo 5093W trop which has "Hi-Fi System" written on the back cover, not on the dial.
- Literatur/Schema (4)
- -- Original-techn. papers.
- Weitere Modelle
-
Hier finden Sie 3571 Modelle, davon 3157 mit Bildern und 2114 mit Schaltbildern.
Alle gelisteten Radios usw. von Telefunken Deutschland (TFK), (Gesellschaft für drahtlose Telegraphie Telefunken mbH
Sammlungen
Das Modell Concertino Hi-Fi Stereo befindet sich in den Sammlungen folgender Mitglieder.
Forumsbeiträge zum Modell: Telefunken: Concertino Hi-Fi Stereo 5093W
Threads: 3 | Posts: 10
Hello,
I have an alignment question about this radio. When I received it, the i.f. rejector circuit coil, marked '10' on the alignment point diagram, was not properly connected. I have reconnected it properly, and I want to make sure that it is adjusted correctly, since it appears to have been replaced by a previous owner.
I have completely re-capped the radio. This is the only alignment I want to attempt, since the radio appears to be working correctly, and all of the other coils and capacitors referenced in the alignment documentation are still sealed with the original wax or sealing compound.
The documentation I refer to is attached to this model on the RM website.
In the alignment procedures for the IF rejector circuit, it is stated that the signal generator should be set to 460 khz, radio set at 800 khz, and the signal generator connected to the radio 'via 10000 pF to Ka 4'. I can find no point in the radio schematic or alignment documentation that is labeled 'Ka 4'.
One of the capacitors which can be adjusted is labelled as 'K', but it is also referenced in the alignment 'sequence' documentation as 'K'.
There are two multiposition switches, marked 'K1' and 'K2', one of which uses position 4 on the 'a' side, but it does not seem to make sense to connect to this position with the signal generator for alignment.
Also, where would I connect to measure minimum output for correct alignment? Across the speaker output or audio output transformer?
Any help would be greatly appreciated. As stated before, the radio appears to be working well so I am going to leave it adjusted as it is until I get an answer here.
Thank you, Joe
Joe Brown, 08.Jun.14
Does anyone know how the knobs connect to the indicators? Is it a cord, a rubber band or something else? Gary
Anlagen
- telefunken (77 KB)
John Kershaw, 13.Dec.06