• Año
  • 1962–1966
  • Categoría
  • Aparato de medida y servicio (Equipo de laboratorio).
  • Radiomuseum.org ID
  • 218333

 Especificaciones técnicas

  • Numero de valvulas
  • 17
  • Numero de transistores
  • 20
  • Semiconductores
  • Gama de ondas
  • - no hay
  • Tensión de funcionamiento
  • Red: Corriente alterna (CA, Inglés = AC) / 115; 230 Volt
  • Altavoz
  • - - No hay salida de sonido.
  • Material
  • Metálico
  • de Radiomuseum.org
  • Modelo: Oscilloscope 130C - Hewlett-Packard, HP; Palo Alto
  • Forma
  • Sobremesa de cualquier forma, detalles no conocidos.
  • Ancho, altura, profundidad
  • 480 x 425 x 180 mm / 18.9 x 16.7 x 7.1 inch
  • Anotaciones
  • The Hewlett Packard model 130C Oscilloscope is a versatile instrument for laboratory, production line, or industrial process measurements. Horizontal and vertical display sensitivity is 200 microvolts per centimeter and the measurement bandwidth is 500 kc. A sweep magnifier of up to X50 allows expansion of a trace to the equivalent of 500 centimeters for viewing waveform details.

    SWEEP GENERATOR
    INTERNAL SWEEP: 21 ranges, 1 µsec/cm to 5 sec/cm, accuracy within +/- 3%.
    Vernier provides oontinuous adjustment between ranges and extends slowest sweep to at least 12.5 sec/cm.
    MAGNIFICATION: X2, X5, X1O, X20, X50 overall sweep accuracy within +/- 5% for sweep rates which do not exceed a maxinwm rate of 0.2 µsec/cm.
    AUTOMATIC TRIGGERING: Base line is displayed in the absence of an input signal.
    Internal: 50 cps to 500 kc signal causing 0.5 cm or more vertical deflection and also from line voltage.
    External: 50 cps to 500 kc, 0.5 volts peak-to peak or more.
    Trigger Slope: Positive or negative slope of external sync signals or internal vertical deflection signals.

    VERTICAL AND HORIZONTAL AMPLIFIERS
    BANDWIDTH:
    DC Coupled: DC to 500 kc
    AC Coupled (input): 2 cps to 500 kc.
    AC Coupled (amplifier): 25 cps to 500 kc at 0.2 mV/cm sensitivity.
    Lower cut-off frequency (fco) is reduced as sensitivity is reduced; at 20 mv/cm fco is 0.25 cps. On less sensitive ranges, response extends to DC.
    SENSITIVITY: 0.2 mV/cm to 20 V/cm. 16 ranges in 1,2,5,10 sequence with an attenuator accuracy within +/- 3%. Vernier permits continuous adjustment of sensitivity between ranges and extends mininwm sensitivity to at least 50 V/cm.
    INPUT IMPEDANCE: 1 megohm shunted by 45 pf, constant on all sensitivity ranges.


    RACK INSTALLATION.
    The Model 130C is shipped from the factory ready for use as a bench instrument. The hardware necessary to rack-mount the instrument is packaged with the instrument.
    90 W power consumption. Tubes listed once per type.
  • Peso neto
  • 14 kg / 30 lb 13.4 oz (30.837 lb)
  • Mencionado en
  • - - Manufacturers Literature (Operating & Service Manual 1966)
  • Autor
  • Modelo creado por Jean-Pierre Gérard. Ver en "Modificar Ficha" los participantes posteriores.