• Year
  • 1959 ??
  • Category
  • Service- or Lab Equipment
  • Radiomuseum.org ID
  • 248994

Click on the schematic thumbnail to request the schematic as a free document.

 Technical Specifications

  • Number of Tubes
  • 4
  • Wave bands
  • Wave Bands given in the notes.
  • Power type and voltage
  • Alternating Current supply (AC) / 60 cycles, 120 Volt
  • Loudspeaker
  • Permanent Magnet Dynamic (PDyn) Loudspeaker (moving coil)
  • Material
  • Metal case
  • from Radiomuseum.org
  • Model: Signal Generator & Tracer KB-141 - Olson Radio Corporation, Olson
  • Shape
  • Tablemodel, with any shape - general.
  • Notes
  • The Olson KB-141 is an AC operated, 4 tube combination signal generator and signal tracer.  The signal generator can output either a modulated or unmodulated signal.

    The RF Bands have the following frequency ranges:
    Band A.............250 - 850kHz
    Band B............850 - 3000kHz
    Band C............3.0 - 11.0MHz
    Band D............11 - 45MHz
    Band E............35 - 120MHz

     

  • Author
  • Model page created by Tim Warneka. See "Data change" for further contributors.

 Collections | Museums | Literature

 Forum

Forum contributions about this model: Olson Radio: Signal Generator & Tracer KB-141

Threads: 1 | Posts: 1

If working on the 4 tube version of  this signal generator / tracer,  please note that terminals 6 and 7 in the schematic diagram are shown  crossed over for the 5687 pre-amplifier tube.  Pin  6  should  the cathode and 7 is the grid.  The tube pin voltage chart  also incorrect.   The same circuits  are used for the Accurate Instruments Model 153 and the schematic diagram for that is correct. 

Christopher Cusick, 04.Sep.18

Weitere Posts (1) zu diesem Thema.